SF-1020 Probench
Computerized Flowbench
The SF-1020 measures and records air flow at OEM engineering accuracy, faster than any other flowbench on the market. It can test up to 240 hp (179 kW) per cylinder at test pressures up to 65" (165 cm) of water. The unique variable flow orifice adjusts flow range between 25 cfm and 1,000 cfm (12 - 472 l/s), based on FlowCom™ input, to fit the valve size or valve lift.
The SF-1020 comes standard with our FlowCom™ digital airflow measurement system for accurate, repeatable and fast testing. FlowCom™ ensures accurate digital airflow measurement and control by automatically measuring test pressure and temperature; then presenting corrected flow data on the easy-to-read, precision display. This saves users considerable time when compared with standard manometer type benches that require users to make calculations to achieve corrected flow numbers.
The included automatic motor controller maintains constant test pressure without the use of knobs and valves and it also helps extend motor life by reducing heat generated during operation. Reduced heat means that operators can run the SF-1020 for longer durations than benches lacking the motor control feature. The large work surface and built-in storage cabinet keep the work area organized and ensure that extra adapters stay clean and out of harms way.
- Flows 1,000 cfm at 65" of water (472 l/s at 165 cm)
- Unique variable flow orifice adjusts between 25 cfm and 1,000 cfm (12 – 472 l/s)
- Includes FlowCom™ digital airflow measurement system
- FlowCom™ provides digital readouts (in English or metric units) for:
- Corrected flow
- Test pressure
- Velocity probe
- Automatically regulates test pressure
- Outputs to optional Port Flow Analyzer™ flowbench software through a serial connection to your computer
- External frequency and load inputs for velocity probe, swirl meter, tumble meter and other devices
- FlowCom™ provides digital readouts (in English or metric units) for:
- Includes automatic motor controller
- Simple electronic switches to select intake or exhaust flow direction
- All digital for accurate, repeatable and fast testing
- Factory calibration
- Operation manual
- 1 year warranty
- Industry leading technical support
± 0.5% of reading in normal operating ranges
± 0.25% of reading
0-1000 cfm (0-470 l/s)
± 0.05" (± 0.13 cm) of water
0-65" (0-165 cm) of water
± 0.5° F (± 0.3° C)
480 lbs (218 Kg)
48" L x 33" W x 43" H (122 x 84 x 110 cm)
730 lbs (332 Kg)
Wooden crate
50" L x 40" W x 59" H (127 x 102 x 150 cm)
240 VAC, 75A, single phase 50/60 Hz